A throughput weigher makes use of a small weighbin to weigh and dump batches in quick succession typically used in bulk handling of cereals. The flexibility of the 6004MF allows you to set high and low levels of the weighbin and various time delays in order to tune the throughput weigher for maximum efficiency. The main LED display can be the resettable totaliser and a non-reset totaliser can be on the auxilliary LCD display

How it works

Select RUN THROUGHPUT WEIGHER if not already in this application. Press side arrow after power up when RUN (application) is displayed, key in password, enter and use side arrows to select, then enter again.

For quicker commissioning first select Security Level 1 and connect the Hardlock link. Going in to the Service menu select Calibrate, not view, in order to change settings. Change Security levels and passwords last. Note that you make changes to the whole Service menu block then press Enter.

It is advisable to first set up the Displays, Digital inputs, Function keys, Throughput Settings, SP Configuration and Setpoint Values, then go to Precalibrate and set up loadcell values and scales. After this you can go through the Service menu blocks to select and set other functions that you may require. Descriptions of these are listed in the Service menu pages.

Final calibration trim can be carried out on the system using Zero Trim and, if test weights are available, Span trim.

The Throughput Weigher Service menu contains the following functions.

Throughput

 

01 Setpoint values Set values for setpoints 1-6
02 Setpoint configuration Select functions for setpoints 1-6
03 Analog output Select output 1-5V, 0-10V, 0-20mA or 4-20mA
04 Communications Select and set up serial output

05 Min/Max Select minimum and/or maximum hold
06 Auto zero Select and set up Auto Zero Maintenance (AZM)
07 Security level Select access to Operator and/or Service menu
08 Precalibrate Set loadcell values, excitation, range, damping

09 Zero trim Trim off empty weighbin
10 Span trim Trim range using test weights
11 Throughput Settings Set totalisers, fill + empty values and timers
12 Lineariser Select up to 15 points of linearising

13 Simulate For testing, force analog and relay outputs
14 Function keys Set functions for keys F1-4
15 Digital inputs Set functions for inputs D1-6
16 Displays Set main display and up to 4 auxiliary on LCD

17 Transmitter settings Set password, calibration, hardware & time/date

 
 
   
   